The state principle, phase change and the vapour dome; how to read a steam table, what enthalpy is for, when a gas is ideal — and why heat capacities climb as molecules start to vibrate.

8 min4 live simulations
you are here
The question

At the base camp of Mount Everest, a climber's tea water boils furiously — at about 70 °C, too cool to brew a decent cup. In a pressure cooker the same water won't boil until 120 °C. And in the boiler of a power station it stays liquid at 300 °C. Why does water boil at 100 °C in Paris but 70 °C on Everest?

Two properties fix a state

The first law tells us how energy moves; to use it, we need numbers for uu, hh and vv of real substances. Happily, we need surprisingly few measurements to pin them down. The state principle says that for a simple compressible substance — one where the only way to do work is by changing volume, which covers water, air and refrigerants — two independent intensive properties fix the state. Choose temperature and pressure, and every other property, from density to entropy, is determined.

The catch is the word independent. During boiling, as you will see in a moment, temperature and pressure are not independent.

The vapour dome

Heat water steadily at constant pressure and watch what happens on the temperature–volume diagram:

ExploreBoiling water, wherever you are
0.0010.010.101101000100200300400500600700specific volume v (m³/kg)temperature (°C)critical pointliquidliquid + vapourvapourp = 1.013 bar100.0 °C
1.013 bar
576 kJ/kg
Temperature100.0 °Csaturated mixture
Quality x10.7% vapour
Specific volume0.180 m³/kg
Enthalpy660 kJ/kg
Challenges0/3
  • Boil water below 72 °C.
  • Boil water at 119 °C or hotter.
  • Turn liquid into vapour without it ever boiling.
One kilogram of water heated at constant pressure, plotted on the temperature–specific volume diagram (volume on a log scale). The dome encloses the states where liquid and vapour coexist. Change the pressure — by going up a mountain, or into a boiler — and the boiling temperature moves with it.

Three regions appear, separated by a bell-shaped curve, the vapour dome:

  • To the left, compressed liquid: water below its boiling point. Its volume barely changes.
  • Under the dome, a two-phase mixture of SaturationThe conditions at which liquid and vapour coexist. At a given pressure there is one saturation temperature: the boiling point. liquid and saturated vapour. Here temperature and pressure are locked together: at 1.013 bar water boils at 100 °C, at 0.314 bar at 70 °C, at 120 bar at 325 °C. Adding heat converts liquid into vapour at constant temperature, and the volume grows enormously.
  • To the right, superheated vapour: steam hotter than its boiling point.

The top of the dome is the Critical pointThe top of the vapour dome — for water 374 °C and 220.6 bar — above which liquid and vapour can no longer be told apart., 374 °C and 220.6 bar for water. Above it, liquid and vapour are indistinguishable: there is no boiling, just a smooth change from dense to light fluid. Modern "supercritical" power stations run their boilers up there, at 250–300 bar, precisely to avoid the constant-temperature boiling step.

Inside the dome, a mixture is described by its Quality xThe mass fraction of vapour in a saturated liquid–vapour mixture, from 0 (saturated liquid) to 1 (saturated vapour)., the mass fraction that is vapour:

x=mvapourmliquid+mvapour,v=vf+x (vg−vf).x = \frac{m_\text{vapour}}{m_\text{liquid} + m_\text{vapour}}, \qquad v = v_f + x\,(v_g - v_f).

The subscripts are the steam-table convention: ff for saturated liquid (from the German flüssig), gg for saturated vapour (gas). The same lever rule works for uu, hh and ss.

Reading a steam table

For a century engineers looked properties up in steam tables: saturated tables indexed by temperature or pressure, and superheated tables giving vv, uu, hh and ss on a grid of (p,T)(p, T), with linear interpolation between grid points. Software has replaced the paper, but the logic is the same: give two independent properties, get the rest.

The temperature–entropy diagram below is a steam table you can drag. (Entropy, ss, arrives properly in Lesson 6; for now treat it as a coordinate that spreads the dome out nicely.)

ToolA steam table you can drag
02468100100200300400500600700entropy s (kJ/kg·K)temperature (°C)0.01 bar0.1 bar1 bar10 bar100 barsuperheated vapourp12.8 barT300.00 °Cv0.1990 m³/kgu2790.0 kJ/kgh3045.5 kJ/kgs7.0000 kJ/(kg·K)x—
Challenges0/2
  • Visit compressed liquid, a wet mixture, superheated vapour and supercritical fluid.
  • Find steam at 1 bar that is 90% vapour.
Drag the point anywhere on the temperature–entropy diagram of water. The panel shows its full state, as you would read it from the steam tables: yellow lines are isobars (constant pressure), dotted lines are constant quality inside the dome. Two independent properties fix the state — here T and s.

Enthalpy: the property that flows

In the table you will find a combination that turns up so often it gets its own name, Enthalpy hh = u + pv: internal energy plus the flow work needed to push the fluid in or out. The natural energy property for flowing streams.:

h=u+pv.h = u + pv.

Its usefulness will become obvious in Lesson 4: when fluid flows into a device, it brings its internal energy and the work needed to push it in, pvpv. Enthalpy bundles the two. For now, notice one thing: across the dome at constant pressure, the heat added per kilogram is exactly the change in enthalpy. The latent heat of vaporisation, hfg=hg−hfh_{fg} = h_g - h_f, is 2257 kJ/kg at 1 atm — over five times the 419 kJ/kg it takes to warm water from 0 to 100 °C.

Estimate first
How much does the volume of water increase when it boils at 1 atm (vapour volume ÷ liquid volume)?
1101001,00010,000100,0001,000,000
Drag along the line to place your guess — each tick is ten times the last.

Liquids and solids: the incompressible model

For liquids, the steam tables barely change with pressure. Compressing water from 1 to 100 bar shrinks it by only 0.5%. It is often good enough to treat liquids and solids as incompressible: vv constant, and uu depends only on temperature, Δu=c ΔT\Delta u = c\,\Delta T, with a single specific heat cc (4.18 kJ/kg·K for water). For the enthalpy, keep the pressure term:

h(T,p)≈hf(T)+vf (p−psat(T)).h(T,p) \approx h_f(T) + v_f\,\big(p - p_\text{sat}(T)\big).

That second term is tiny for most purposes — but, as the pump in Lesson 4 will show, it is the whole story when you pressurise a liquid.

Gases: when is the ideal-gas law good enough?

For gases, the ideal-gas law pv=RTpv = RT is beautifully simple. But it ignores the size of molecules and the forces between them, and those matter when molecules are crowded — at high pressure or near condensation. The compressibility factor measures the error:

Z=pvRT.Z = \frac{pv}{RT}.

Remarkably, when pressure and temperature are scaled by their critical values — pR=p/pcp_R = p/p_c, TR=T/TcT_R = T/T_c — most gases fall on nearly the same Compressibility factor ZZ = pv/RT. Equal to 1 for an ideal gas; it measures how far a real gas departs from ideal behaviour.:

ExploreWhen is a gas ideal?
02468100.20.40.60.811.21.4reduced pressure p_R = p / p_cZ = pv / RTideal gas ± 5%T_R=1T_R=1.1T_R=1.3T_R=1.6T_R=2
300 K · T_R = 2.38
100 bar · p_R = 2.94
Compressibility Z0.989gas
Ideal-gas law error+1.2%in predicted density
Reduced state2.38, 2.94T_R, p_R
Challenges0/2
  • Find a gas state where the ideal-gas law is off by more than 20%.
  • Find a state above 50 bar where the ideal-gas law is still within 2%.
The generalised compressibility chart: Z = pv/RT against reduced pressure p/p_c, for several reduced temperatures T/T_c (curves from the Peng–Robinson equation of state). An ideal gas has Z = 1 everywhere. Pick a gas and a state: the dot shows where it sits.

The rule of thumb that falls out: a gas is close to ideal when its pressure is low compared with its critical pressure (pR≪1p_R \ll 1) or its temperature is well above critical (TR≳2T_R \gtrsim 2). Air at room conditions is both: TR≈2.3T_R \approx 2.3, pR≈0.03p_R \approx 0.03, Z=0.9997Z = 0.9997. Steam in a power-plant boiler is neither — which is why we need steam tables at all.

Check your intuition
Is the ideal-gas model reasonable for superheated steam at 0.1 bar and 100 °C, in a power-plant condenser?

Ideal-gas internal energy and enthalpy

For an ideal gas, molecules don't feel each other, so their internal energy can't depend on how far apart they are: uu and hh depend on temperature alone. Then

du=cv(T) dT,dh=cp(T) dT,cp−cv=R.du = c_v(T)\,dT, \qquad dh = c_p(T)\,dT, \qquad c_p - c_v = R.

The difference cp−cv=Rc_p - c_v = R is the extra energy it takes, at constant pressure, to push back the surroundings as the gas expands. The specific heats themselves come from the molecules — and they are not constants.

ExploreMolecules wake up as they warm
1002005001000200040002345678temperature (K)c_p / RArN₂H₂OCO₂translation1.50 Rrotation1.00 Rvibration0.00 Rp·v work (R)1.00 R
300 K
c_p1.039 kJ/(kg·K)3.50 R per mole
γ = c_p / c_v1.400
Challenges0/3
  • Find the gas whose γ is 5/3 at every temperature.
  • Heat nitrogen until its vibration is at least half awake.
  • Push γ of a gas below 1.15.
The molar heat capacity c_p of four gases, in units of the gas constant R, from a model in which molecules translate, rotate and vibrate as quantum oscillators. Each vibration only joins in once the gas is hot enough to excite it — so heat capacities climb with temperature, and γ = c_p/c_v falls.

The equipartition picture explains the numbers. Each way a molecule can store energy "freely" contributes 12R\tfrac12 R to cvc_v: three directions of translation give every gas 32R\tfrac32 R; a linear molecule adds two rotations, a bent one three. Vibrations are different: they are quantised, and a vibration with a characteristic temperature of 3390 K, like nitrogen's, simply cannot be excited at room temperature. As the gas heats up, one vibration after another "wakes up", and cpc_p climbs.

That is why the hot gas in a gas turbine has γ≈1.3\gamma \approx 1.3 instead of air's familiar 1.4 — and why accurate cycle calculations use ideal-gas tables of h(T)h(T) instead of a constant cpc_p. The course's models do the same.

Going deeper
Going deeper: the cold-air standard and when to use it

For quick estimates, Moran and Shapiro use the cold-air-standard assumption: air with constant specific heats evaluated at 300 K, cp=1.005c_p = 1.005 kJ/(kg·K), cv=0.718c_v = 0.718, k=1.4k = 1.4. It turns every process into closed-form algebra — for example, an isentropic process obeys T2/T1=(p2/p1)(k−1)/kT_2/T_1 = (p_2/p_1)^{(k-1)/k}.

It is accurate to a few percent below about 600 K. Above that, vibrations of N₂ and O₂ (and, in combustion products, of CO₂ and H₂O) raise cpc_p by 10–25%, and the constant-cpc_p model overpredicts temperatures and efficiencies. Variable-property calculations integrate cp(T)c_p(T), which is what the tables of h(T)h(T) and s∘(T)s^\circ(T) do for you.

Recap
What to carry forward
  • State principle: two independent intensive properties fix the state of a simple compressible substance.
  • Under the vapour dome, temperature and pressure are tied together: lower the pressure and water boils cooler. The dome ends at the critical point (374 °C, 220.6 bar).
  • In the two-phase region, quality xx interpolates every property: v=vf+xvfgv = v_f + x v_{fg}.
  • Enthalpy h=u+pvh = u + pv; at constant pressure, the heat added equals the enthalpy rise.
  • Liquids are nearly incompressible. Gases are nearly ideal when p≪pcp \ll p_c or T≫TcT \gg T_c; the compressibility factor ZZ measures the error.
  • For ideal gases, uu and hh depend only on TT, and cpc_p rises with temperature as molecular vibrations wake up.

Next: open the system up. How do you apply energy conservation to turbines, pumps and nozzles that fluid flows straight through?